Load Sensor

Overload, illegal dumping, unauthorized using of vehicles, fuel theft, illegal operation have been growing problems with the fast development of truck logistics. At one time, the administrators had been helpless and obviously traditional solutions such as truck scale are not ideal for its high cost, high error and failure rate.Based on the issues above, Soway Tech Ltd designs and produces a brand new load sensor, SAHX series, which has a longer life-expectancy and higher accuracy. 

 

Load sensor                                            

Load sensor

SAHX-120B

Output signal

Accurency
Range scope

Working temperature(℃)

角度載重傳感器-深圳信為研發(fā)  產(chǎn)品 (熱門產(chǎn)品 - 3*) 

0.5-4.5V/CAN/RS485

±2%(F.S)

0-120℃

-40~ 70

 

Load sensor

Output style

linear error(%)

Working temperature(℃)

 https://my.diytrade.com/diyep/siteMain/page/editor?rp_em=2&rp_ene=Page&rp_eid=7839132&pageID=7839132&page=page/editor#

- No load/full load/overload

±5

-20~ 85

-Continuous analog quantity

±5

-20~ 85

It can detect the no-load, full load, overload and partial load state of the muck car, mud truck, coal truck, ore car and other cars.

 

Position sensor/lift sensor
 

Model Principle

Contact

form

output method

Power supply type

action distance(mm)

 

P119

Reed

switch

principle

Normally open/normally closed optional

ON/OFF switch signal high and low level

24V DC以下

Power supply 39-41 (iron plate)
83-85 (non-iron plate parallel test)

SPH119

Hall

principle

/ 0~5V 9~28 VDC non-iron plate parallel test 0~25mm
 

 

Airtight sensor SP1191 series

Model

Supply

voltage

Contact

form

trigger distance output method Operating temperature range action distance

trigger method

SP1191-A

12~30 VDC

 

≤15mm

(face to face trigger)

No trigger, output 5V, green light is always on


When triggered, the output is 2.5V, and the green light is dim


The thread is cut, the output is 0V, and the light is off

-30~+120℃ ≤100mm

(Parallel movement after face-to-face trigger)

magnet trigger

SP1191-B

12~24 VDC

Type A

contact
(normally open)

≥20mm Switch


When triggered, turn on


No trigger, disconnected

-25~+80℃   magnet trigger
SP1191-C   Form A contact (normally open)   High and low level output


Trigger (when airtight): high level light is on


Leave (when open): low level light off

-25~+80℃    

It can detect the lifting and lifting of dump truck, muck truck, dump truck, garbage truck bucket and car.

 

 

Positive and reverse tachometric transducer    

Positive and reverse tachometric transducer

SPH3A0-10B-V-MEP10

output mode

Supply voltage

Detector detection distance(mm)

working environment

Open-collector output
 

DC 5V~24V

 

 5-10

Temperature-20~80℃

Humidity≤90%

                                    

Temperature and humidity measurement

 

ST116/117

Analog signal temperature sensor

Supply voltage
Measuring range

 

Accuracy of detection

Output signal

 

Housing

3.0~5.5 VDC

-40 ℃ ~ +85 ℃

±1 ℃

(0 ℃~+70 ℃)

linear voltage
:0℃-500mV,10mV/℃
Stainless steel 316
±0.5℃(-10~+85℃) Single bus data communication

  Widely used in cold chain logistics transportation, agriculture, forestry, meteorological environment, greenhouse, laboratory, Internet of things system and other industries as well as climate room, warehouse

Storage, ship, dock, flower cultivation, pharmacy, supermarket warehouse, museum, fog spray intelligent control system and other places.

T119 Temperature Sensor

Supply voltage
Measuring range

 

Accuracy

Output signal

 

Protecion Grade

5 VDC

-40 ℃ ~ +80 ℃

±0.5 ℃

(0 ℃~70℃ )

 

Modbus RS485 IP67

 

ST118 Temperature and
humidity sensor

Supply voltage

Measuring range

Output signal

Housing

5 VDC(Current≤15mA)

Temperature:±0.2℃(0~+60℃)

Humidity:2%(25℃)

RS485(MODBUS)

Flame retardant engineering plastics UL94-V0

oil measurement sensor   

Reed tube type oil level sensor

output mode

input/output range

Outgoing way

Installation methods

Material Action point spacing measurement accuracy Range scope Float Working temperature

Resistive output
(no transmitter)

input:no

output:KΩ

Second line out

(A junction box can be added)

Thread, flange

 

SUS304

SUS316

5mm-10mm ±5mm

±10mm

0.1m-1m NBR Float -40℃~+85℃
Voltage output
(with transmitter)

 
input range:12V(24V)

output range:0-5V(1-10V)

error range:0.3V

Three line out

(A junction box can be added)
Current output
4-20mA
(with transmitter)
input:24V

output:4-20mA

Add a junction box for three wires

                                             

Fuel consumption
meter

HOCM03

Accuracy of measurement

Flow range

Working temperature

Product material Working voltage Digital output (one can be selected) Oil circuit interface

±1%

10-450 L/H

-20℃~80℃

aluminum 24V DC RS232 interface (1 way)

RS485 interface (1 way)

M14*1.5

 

Back to Top